Part Number
Part Number:
NSN:
NIIN:
Item Name:
TEST SET , TELECOMMUNICATION SYSTE
Definition:
A TEST SET DESIGNED FOR USE IN EXAMINING A TELECOMMUNICATION SYSTEM OR SUBSYSTEM, AND PROVIDING DISCREET EVALUATION OF ITS PERFORMANCE. ITS TESTING CAPABILITIES ARE MULTIAPPLICATION AND NOT LIMITED TO MEASURING SINGLE PERFORMANCE CHARACTERISTICS. PROVIDES THE FACILITIES FOR VOICE-GRADE, PROGRAM AND/OR DATA LINE TESTING.
CAGE Information
Code | Company |
---|---|
61141 | ACTERNA LLC DBA JDSU |
Federal Supply Class
Title
ELECTRICAL AND ELECTRONIC PROPER
Inclusions:
INCLUDES TEST LEADS AND TEST LEAD ATTACHMENTS; TEST INSTRUMENTS DESIGNED FOR COMMUNICATION EQUIPMENT; TEST INSTRUMENTS DESIGNED FOR USE WITH ELECTRONIC EQUIPMENT CLASSIFIED IN TWO OR MORE FSC GROUPS.
Exclusions:
EXCLUDES RADIAC EQUIPMENT
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ANPZ | INCLOSURE FEATURE | SINGLE ITEM W/HOUSING |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
AGAV | END ITEM IDENTIFICATION | AN/FTC-31 COMMUNICATION SYSTEM |
AQXY | TEST TYPE FOR WHICH DESIGNED | COMMUNICATION ANALYZER PERFORMS MANY DATA CIRCUIT TESTS AND FUNCTIONS INCLUDING ERROR ANALYSIS,MESSAGE GENERATION AND ANALYSIS,DATA TRAPPING,DISTORTION AND DELAY MEASUREMENTS,CLOCK FREQUENCY MEASUREMENTS AND VOICE FREQUENCY MEASUREMENTS |
ACYN | AC VOLTAGE RATING | 100.0 VOLTS MINIMUM AND 240.0 VOLTS MAXIMUM |
ABGL | WIDTH | 17.250 INCHES NOMINAL |
FTLD | FUNCTIONAL DESCRIPTION | MEASURES THE DELAY TIME BETWEEN ANY TWO SELECTED EVENTS;MEASUREMENTS STARTS THE RISING OR FALLING EDGE OF DTR,DSR,RTS,CTS,CD,GENERATOR DATA,END OF TRANSMISSION OR REAR PANEL INPUT X;ENDS ON DETECTION OF THE RISING OR FALLING EDGE OF DTR,DSR,RTS,CTS,CD,RECEIVE DATA,DETECTION OF TRAP CHARACTERS OR REAR PANEL INPUT Y |
AEJZ | DEPTH | 13.500 INCHES NOMINAL |
HGTH | HEIGHT | 5.250 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 48.0 HERTZ MINIMUM AND 66.0 HERTZ MAXIMUM |
FEAT | SPECIAL FEATURES | OPERATING MODES ARE FULL DUPLEX,HALF DUPLEX CONTINUOUS,HALF DUPLEX SINGLE,SINGLE TRANSMIT,AND SELF TEST MODE;TIMING IS SYNCHRONOUS AND RECOVERED CLOCK FROM 10 B/S TO 500 KB/S;ASYNCHRONOUS FROM 10 B/S TO 20 KB/S;REMOTE AND AUTOMATIC TESTING VIA RS-232,IEEE-488 OR HP-IL CONTROL INTERFACES |
FAAZ | PHASE | SINGLE |